Nodule tracking for differential measurements. Utilizing ClearRead CT Detect, ClearRead CT Compare tracks nodules and provides nodule volumetric changes over time for solid, part-solid, and ground glass nodules.
Product specifications Information source: Vendor
Last updated: April 19, 2022
General
Product name ClearRead CT - Compare
Company Riverain Technologies
Subspeciality Chest
Modality CT
Disease targeted Lung cancer
Key-features Multiple time-point analysis
Suggested use During: report suggestion
Data characteristics
Population Adult population, not cleared for pediatric use.
Input Multislice CT scan, contrast or non-contrast, pre-fetched priors
Input format DICOM
Output Summary report with relevant overlayed image patches and measurements and growth rate/doubling time
Output format DICOM
Technology
Integration Integration in standard reading environment (PACS)
Deployment Locally on dedicated hardware, Locally virtualized (virtual machine, docker)
Trigger for analysis Automatically, right after the image acquisition
Processing time 1 - 10 minutes
Certification
CE
Certified, Class IIa , MDR
FDA
510(k) cleared, Class II
Market presence
On market since 11-2015
Distribution channels Sectra Amplifier Store, Aidoc aiOS, GE Healthcare Edison platform, Eureka Clinical AI, Philips AI Marketplace, Agfa PACS, Blackford Marketplace, Fuji PACS, Calantic
Countries present (clinical, non-research use)
Paying clinical customers (institutes)
Research/test users (institutes)
Pricing
Pricing model Subscription
Based on Number of analyses
Evidence
Peer reviewed papers on performance
Non-peer reviewed papers on performance Case Studies
Other relevant papers