CINA-ICH
Avicenna.AI
Information source:
Vendor
Last updated: September 4, 2024 |
General Information
General | |
---|---|
Product name | CINA-ICH |
Company | Avicenna.AI |
Subspeciality | Neuro |
Modality | CT |
Disease targeted | Intracranial Hemorrhage, Stroke, Trauma |
Key-features | Intracranial Hemorrhage detection, notification |
Suggested use | Before: adapting worklist order, flagging acute findings |
Technical Specifications
Data characteristics | |
---|---|
Population | Suspicion of stroke, Suspicion of head trauma |
Input | Non contrast CT |
Input format | DICOM |
Output | segmentation contour, worklist order, notification |
Output format | DICOM SC, GSPS |
Technology | |
Integration | Integration in standard reading environment (PACS), Integration via AI marketplace or distribution platform |
Deployment | Locally on dedicated hardware, Locally virtualized (virtual machine, docker), Cloud-based |
Trigger for analysis | Automatically, right after the image acquisition |
Processing time | 10 - 60 seconds |
Regulatory
Certification | |
---|---|
CE |
Certified,
Class IIb
, MDR
|
FDA | 510(k) cleared , Class II |
Intended Use Statements | |
Intended use (according to CE) | CINA is a radiological computer aided triage and notification software indicated for use in the analysis of (1) non-enhanced head CT images and (2) CT angiographies of the head. The device is intended to assist hospital networks and trained radiologists in workflow triage by flagging and communicating suspected positive findings of (1) head CT images for Intracranial Hemorrhage (ICH) and (2) CT angiographies of the head for large vessel occlusion (LVO). CINA uses an artificial intelligence algorithm to analyze images and highlight cases with detected (1) ICH or (2) LVO on a standalone Web application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for cases with suspected ICH or LVO findings. Notifications include compressed preview images that are meant for informational purposes only, and are not intended for diagnostic use beyond notification. The device does not alter the original medical image, and it is not intended to be used as a diagnostic device. The results of CINA are intended to be used in conjunction with other patient information and based on professional judgment to assist with triage/prioritization of medical images. Notified clinicians are ultimately responsible for reviewing full images per the standard of care. |
Market
Market presence | |
---|---|
On market since | 02-2020 |
Distribution channels | Eureka Clinical AI, Canon Automation Platform, Blackford, Tempus Pixel, Nuance PIN, Sectra Amplifier Store, deepcOS, Incepto, CARPL.ai, Calantic |
Countries present (clinical, non-research use) | |
Paying clinical customers (institutes) | |
Research/test users (institutes) | |
Pricing | |
Pricing model | Pay-per-use, Subscription |
Based on | Number of installations, Number of analyses |
Evidence
Evidence | |
---|---|
Peer reviewed papers on performance |
|
Non-peer reviewed papers on performance | |
Other relevant papers |